Article ID Journal Published Year Pages File Type
190683 Electrochimica Acta 2011 5 Pages PDF
Abstract

We have synthesized graphene and Pt-graphene hybrid material by a microwave-assisted chemical reduction process and evaluated their application as electrode materials towards the electrochemical detection of hydroquinone. Graphene modified glass carbon electrode (GCE) showed a good performance for detecting hydroquinone due to the unique properties of graphene which increased the active surface area of the electrode and accelerated the electron transfer. The linear detection range of hydroquinone concentration was 20–115 μM with a sensitivity of 1.38 μA μM−1 cm−2; the detection limit was estimated to be 12 μM (S/N = 3). The electrocatalytic activity of the Pt-graphene modified GCE was further improved due to the enhanced electron transfer and the linear detection range was 20–145 μM with the sensitivity of 3.56 μA μM−1 cm−2, detection limit 6 μM (S/N = 3).

Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Engineering (General)
Authors
, , ,