Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
2058702 | MethodsX | 2014 | 4 Pages |
Lactic acid is a valuable and fully degradable organic acid with promising applications in poly-lactic acid production (Taskila S and Ojamo, 2013 [1]). Despite their efficiency, the cost of the current lactic acid bio-processes is still an obstacle to this application (Miller et al., 2011 [2]). To ameliorate lactic acid producing strains, researchers are using mutations and metabolic engineering techniques, as well as medium optimization. All these studies necessitate a good and high throughput screening method. Currently, researchers mostly use HPLC methods which often necessitate sample preparation, are not stereospecific and do not allow high throughput. To help optimizing l-lactic acid production, we developed a high throughput colorimetric method inspired by the blood l-lactic acid detection method used for diagnosis (Lin et al., 1999 [3]).•Two sequential enzymatic reactions using l-lactate oxidase, peroxidase and ABTS (2,2′-azino-di-[3-ethylbenzthiazoine-sulfonate]), a chromogenic peroxidase substrate, are used to quantify l-lactate between 13.8 and 90 mg/l.•The accuracy of the method was ascertained before automation.•The method was successfully applied for the direct determination of l-lactate content in fungal culture supernatants.