Article ID Journal Published Year Pages File Type
2159763 Radiotherapy and Oncology 2009 9 Pages PDF
Abstract

PurposeThe aim of this study was to compare the dose calculation accuracy of advanced kernel-based methods and Monte Carlo algorithms in commercially available treatment planning systems.Materials and methodsFollowing dose calculation algorithms and treatment planning (TPS) systems were compared: the collapsed cone (CC) convolution algorithm available in Oncentra Masterplan, the XVMC Monte Carlo algorithm implemented in iPlan and Monaco, and the analytical anisotropic algorithm (AAA) implemented in Eclipse. Measurements were performed with a calibrated ionization chamber and radiochromic EBT type films in a homogenous polystyrene phantom and in heterogeneous lung phantoms. Single beam tests, conformal treatment plans and IMRT plans were validated. Dosimetric evaluations included absolute dose measurements, 1D γ-evaluation of depth–dose curves and profiles using 2 mm and 2% dose difference criteria for single beam tests, and γ-evaluation of axial planes for composite treatment plans applying 3 mm and 3% dose difference criteria.ResultsAbsolute dosimetry revealed no large differences between MC and advanced kernel dose calculations. 1D γ-evaluation showed significant discrepancies between depth–dose curves in different phantom geometries. For the CC algorithm γmean values were 0.90 ± 0.74 vs. 0.43 ± 0.41 in heterogeneous vs. homogeneous conditions and for the AAA γmean values were 1.13 ± 0.91 vs. 0.41 ± 0.28, respectively. In general, 1D γ results obtained with both MC TPS were similar in both phantoms and on average equal to 0.5 both for profiles and depth–dose curves. The results obtained with the CC algorithm in heterogeneous phantoms were slightly better in comparison to the AAA algorithm. The 2D γ-evaluation results of IMRT plans and four-field plans showed smaller mean γ-values for MC dose calculations compared to the advanced kernel algorithms (γmean for four-field plan and IMRT obtained with Monaco MC were 0.28 and 0.5, respectively, vs. 0.40 and 0.54 for the AAA).ConclusionAll TPS investigated in this study demonstrated accurate dose calculation in homogenous and heterogeneous phantoms. Commercially available TPS with Monte Carlo option performed best in heterogeneous phantoms. However, the difference between the CC and the MC algorithms was found to be small.

Keywords
Related Topics
Life Sciences Biochemistry, Genetics and Molecular Biology Cancer Research
Authors
, , , , , ,