Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
222705 | Journal of Food Engineering | 2016 | 8 Pages |
•Ohmic heating technology is appropriate for sterilization of heat sensitive products.•Ohmic heating is comparable to steam injection for UHT sterilization.•Equivalent nutritional quality of the liquid infant formula is obtained.•Accumulation of Maillard products can be described by a simple Arrhenius model.
A continuous pilot plant for liquid sterilization was used to compare ohmic heating and steam injection on liquid infant formula under the same conditions of pre-heating and holding. Samples were collected at different holding times and temperatures and analyzed for reactions of thermal degradation. Two substrates were measured: soluble proteins and vitamin C and different intermediate or advanced products of Maillard reaction were monitored: furosine, carboxymethyllysine (CML), FAST index (Fluorescence of Advanced Maillard products and Soluble Tryptophan) and color (ΔL*, Δa* and Δb*). Pseudo-zero order kinetics was established for the Maillard products or global markers and Arrhenius parameters could be calculated. Equivalent markers contents were obtained after ohmic heating and steam injection showing equivalent quality of the infant formula for both sterilization technologies.