Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
226362 | Journal of Food Engineering | 2006 | 9 Pages |
Abstract
A system for monitoring milk and fat concentration in a dynamic milk/water system by fusing information from several sensors was investigated. Standard instrumentation for food production was used, the sensors were a conductivity meter, a density meter and an optical instrument used to measure backscattered light. The system was applied to a dynamic mixing situation. Prediction error did not exceed 2% in the milk concentration and 0.1% fat in the total fat concentration. The applicability of the sensor fusion approach in field conditions was demonstrated by mounting the sensors in a dairy plant and monitoring the start-up of a pasteurizer.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Chemical Engineering (General)
Authors
Marcus Henningsson, Karin Östergren, Rolf Sundberg, Petr Dejmek,