The influence of the adapter type (rolling bearing, stiff cylindrical element) between coactive and load taking heads on stability and vibrations of Euler loaded columns has been analysed in this paper. Using a stiff cylindrical element in the load charging heads, in comparison to a rolling element, makes the rotating loop stiff between the two cooperating structure loading elements.
Keywords
Related Topics
Physical Sciences and Engineering
Engineering
Civil and Structural Engineering
Authors
A. KASPRZYCKI, L. TOMSKI,