Article ID Journal Published Year Pages File Type
248934 Building and Environment 2011 12 Pages PDF
Abstract

Solar heated tall ventilation cavities including solar chimneys are used to enhance natural ventilation of buildings. A validated CFD model was used to predict the buoyancy-driven air flow and heat transfer rates in vertical ventilation cavities with various combinations of heat distribution on two vertical walls ranging from symmetrical to fully asymmetrical heating. The natural ventilation rate and heat transfer rate have been found to vary with the total heat input, heat distribution on the cavity walls, cavity width and height and inlet opening position. General expressions for these variables have been obtained and presented in non-dimensional terms, Nusselt number, Reynolds number, Rayleigh number and aspect ratio (H/b), as Nu = f(Ra, H/b) and Nu = f(Ra, Re) or Re = f(Ra, Nu), for natural ventilation design.

► General expressions for calculating ventilation rate and heat transfer rate. ► Heat transfer rate Nu = f(Ra). ► Ventilation rate Re = f(Nu, Ra). ► Suitable for design of tall ventilation structures.

Related Topics
Physical Sciences and Engineering Energy Renewable Energy, Sustainability and the Environment
Authors
,