Article ID Journal Published Year Pages File Type
260943 Construction and Building Materials 2006 8 Pages PDF
Abstract

This study is to relate the mechanical and durability properties of high performance metakaolin (MK) and silica fume concretes to their microstructure characteristics. The compressive strength and chloride penetrability of the control and the concretes incorporated with MK or silica fume (SF) at water-to-binder (w/b) ratios of 0.3 and 0.5 are determined. The pore size distribution and porosity of the concretes are also measured. The effect of MK and SF on the interfacial porosity is discussed based on test results. It is found that MK concrete has superior strength development and similar chloride resistance to SF concrete, and the MK concrete at a w/b of 0.3 has a lower porosity and smaller pore sizes than the control (plain) concrete. The resistance of the concretes to chloride ion penetration correlates better with the measured concrete porosity than with the paste porosity. The differences between the measured and calculated concrete porosity is smaller for MK and SF incorporated concrete than for the control concrete, indicating an improvement in the interfacial microstructure with the incorporation of the pozzolanas. This difference is found to be related to the strength and chloride penetrability of concrete to some degree.

Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering
Authors
, , ,