Article ID Journal Published Year Pages File Type
261068 Construction and Building Materials 2007 11 Pages PDF
Abstract

The results of the ambient-vibration based investigations carried out to assess the structural conditions of a masonry bell-tower are presented. The tower, dating back to the XVII century and about 74 m high, is characterised by the presence of major cracks on the western and eastern load-bearing walls.The assessment procedure includes full-scale ambient vibration testing, modal identification from ambient vibration responses, finite element modelling and dynamic-based identification of the uncertain structural parameters of the model. A good match between theoretical and experimental modal parameters was reached for relatively low stiffness ratios in the most damaged regions of the tower. Furthermore, the model identification, carried out by using two different methods, provided consistent structural parameters which are also in close agreement with the available characterization of the materials.

Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering
Authors
, ,