Article ID Journal Published Year Pages File Type
270219 Fire Safety Journal 2009 12 Pages PDF
Abstract

Four full-scale reinforced concrete (RC) columns with L-shaped cross-sections, four full-scale RC columns with T-shaped cross-sections, three full-scale RC columns with +-shaped cross-sections, and one full-scale RC column with a square cross-section were experimentally investigated for fire resistance following the ISO834 standard heating process. The effects of axial load ratio and fire exposure condition on failure mode, axial deformation and fire resistance of the columns were analyzed. The experimental results showed that: (a) when the axial load ratio is 0.55, the fire resistances of the columns with L-, T-, and +-shaped cross-sections subjected to fire on all sides were 60–73% that of the column with the square cross-section. (b) In the case of samples subjected to fire on all sides, the fire resistance of columns with differently-shaped cross-sections increased in the following order: L-shaped cross-section

Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering
Authors
, ,