Article ID Journal Published Year Pages File Type
270397 Fire Safety Journal 2007 14 Pages PDF
Abstract

This paper discusses the development of a smoke model for CFD. The model evaluates smoke visibility based on line of sight. Using a compartment fire, the deficiency in determining visibility by the conventional surface-based approach is first demonstrated. Smoke management in an underground rail station is investigated using the smoke model. For a medium growth rate fire, the results show that the platform is blocked by smoke within 2–3 min. On the mezzanine, the designed smoke exhaust controls the smoke only for a limited time of less than 4 min. The variations of smoke obscuration are quantified at three locations, which are used to start the tunnel ventilation at 4 min. This can be related to a video-based smoke detection. The smoke model would be useful in tenability, egress and other life safety assessments. Future development of the model includes local lighting effects and experimental validation.

Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering
Authors
,