Article ID Journal Published Year Pages File Type
271589 Fusion Engineering and Design 2013 6 Pages PDF
Abstract

In the ITER tokamak, the toroidal magnetic field (TF) ripple is estimated with TF coils only, with the installation of ferromagnetic inserts (FIs), and with test blanket modules (TBMs) by using a 2-D code for easy and fast calculation. We assessed the effects of the thickness of the FIs on the TF ripple in order to optimize the FI. And we analyzed how the TBMs distort the TF, and calculated the TF ripple for various amounts of a ferromagnetic material and the positions of the TBMs. Even in the case of moving the TBMs outward up to 60-cm, and reducing the ferromagnetic material to 52%, the TF ripple is not decreased below 0.38%. So we had to adopt ripple correction coils. With a 52% reduced amount of the ferromagnetic material in a TBM, we could reduce the TF ripple to 0.28% at a coil current of 100 kA turn per each coil. And with an outward recess of the TBM up to 60 cm, we could reduce the TF ripple to 0.23% at a coil current of 250 kA turn per each coil. As a combined approach, if we reduce the amount of a ferromagnetic material in a TBM to 30%, and recess the TBM to 15 cm, we can efficiently obtain the TF ripple of 0.25% at a coil current of 150 kA turn per each coil.

Keywords
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , ,