Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
271592 | Fusion Engineering and Design | 2013 | 4 Pages |
For economic and safety reasons, tritium (T) accumulation on plasma facing wall (PFW) of fusion reactor is strictly limited. In this study, T inventory in the graphite tiles used at the first wall of JT-60U was measured by a full combustion method. It was found that T was only retained near plasma facing surfaces sides of the tiles and the amount of retained T increased from <1011 to <1013 T atoms/cm2 with increasing the exposed discharge period of the tiles. Integrating the T retention with the total surface area of the outer first wall tiles, the fraction of retained T in that area was estimated to be 13% of the total T production. It was confirmed that these retained T were part of the energetic T produced by DD reactions without being replaced by HH discharges. Based on the retained fraction, the annual amount of T retention in the outer first wall of a demo-size reactor was calculated to be 360 g/burn-year at maximum. Even the value would be much less in the reactor, the accumulation of this kind of inventory could have significant contribution to the total T inventory.