Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
2715997 | The Journal of Foot and Ankle Surgery | 2009 | 4 Pages |
Abstract
A wide range of options is available to surgeons for fixation of the proximal interphalangeal joint when arthrodesis is undertaken for repair of the hammertoe deformity. In this technical report, we describe the use of an intraosseous loop of stainless-steel wire for permanent stabilization of the interface between the proximal and middle phalanges during fusion of the interphalangeal joint.
Related Topics
Health Sciences
Medicine and Dentistry
Orthopedics, Sports Medicine and Rehabilitation
Authors
William Harris IV, Gregory A. Mote, D. Scot Malay,