Article ID Journal Published Year Pages File Type
2717984 The Foot 2012 7 Pages PDF
Abstract

BackgroundIn-shoe center of pressure (COP) measurement is essential in biomechanics. COP can be measured directly utilizing pressure-sensitive insoles, or calculated indirectly via force plate-generated data. While the latter does not require the use of additional measurement hardware (shoe insoles), its precision at calculating in-shoe COP has not been determined. Our purpose was to ascertain the precision of force plate in-shoe COP calculations and enhance their accuracy through a mathematical algorithm.MethodsTwelve male students participated in the study. In-shoe COP was measured synchronously via the Pedar-X insole system and AMTI force plates, comparing the measurements of both systems. A mathematical algorithm was created to improve agreement between the systems and comparisons were recalculated.ResultsThe two methods showed different measurements of in-shoe COP. The medio-lateral (ML) and anterior-posterior (AP) Pearson correlation coefficients between systems were 0.44 ± 0.35 and 0.99 ± 0.01, and the ML and AP RMS errors were 6.3 ± 3.0 mm and 43.0 ± 12.5 mm, respectively. Using a mathematical algorithm, the differences between the measurements of each system could be reduced significantly (all P < 0.001).ConclusionsWithout adjustment, force plates give an approximate location of the COP. Using an adjustment model greatly improves the accuracy of the COP trajectory during stance.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, , , , , , ,