The main topic of an ITER blanket first wall procurement is to qualify whether each party has the key technology needed for the fabrication and joining of first wall components. A semi-prototype qualification project will be released requiring that the single components of a full-scale first wall must be fabricated and successfully pass high heat flux tests using a hypervapotron cooling channel. In this work, various mockup types have been modeled and fabricated to develop the joining technology for a semi-prototype. The semi-prototype, which has three double-fingered panels, is a scaled-down component of a full-size first wall. The standard or slit mockups with a 80 mm × 80 mm single beryllium tile joined to a CuCrZr heat sink were fabricated to qualify our HIP (Hot Isostatic Pressing) technology for the joining of semi-prototype. These standard mockups were installed to perform a high heat flux test in the Korea heat load test facility (KoHLT). For a preliminary test of a semi-prototype, thermo-hydraulic mockups of 710 mm × 100 mm were designed and fabricated to verify the Cu/SS cooling performance, such as hypervapotron. For the high heat flux test in our KoHLT facility, the normal cycle is based on an expected heat flux of 300 s in accordance with the ITER qualification specifications. These tests will be performed to qualify the joining technologies, which is required for an ITER blanket first wall and a semi-prototype.