Abstract

As an important component of Dual Functional Lithium Lead-Test Blanket Module (DFLL-TBM), the first wall (FW) must withstand and remove the heat flux from the plasma (q″ = 0.3 MW/m2) and high nuclear power deposited in the structure at normal plasma operation scenario of ITER. In this paper the transverse ribs arranged along the plasma facing inner wall surface were used to enhance the heat transfer capability. After the validation compared with empirical correlations the Standard k–ω model was employed to do the numerical simulation using FLUENT code to investigate the heat transfer efficiency and flow performance of coolant in the ribbed channel preliminarily. The perforation on the bottom of rib was proposed near the lower heat transfer area (LHTA) to improve the heat transfer performance according to results of analyses.

Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , ,