Article ID Journal Published Year Pages File Type
272081 Fusion Engineering and Design 2012 4 Pages PDF
Abstract

For safe operation and maintenance of nuclear devices, it is very important to predict the dose rate distribution after shutdown. Based on the rigorous two-step (R2S) method, a new shutdown dose rate calculation code system was developed for nuclear devices with large dimension and complex geometries. By coupling the Monte Carlo particle transport calculation code MCNP with the activation simulation code FISPACT, the dose rate calculation codes integrate the functions of neutron transport calculation, activation calculation and decay gamma transport calculation. This code system was applied to the shutdown dose analysis for experimental advanced superconducting tokamak (EAST). Three-dimensional dose rate distributions of the EAST for different cooling times and spatial locations were obtained. The results can be used to assist radiation protection in EAST.

► Based on R2S method, a shutdown dose rates calculation code was developed. ► The shutdown dose calculation code can automatically calculate the dose rates accurately without manual calculations. ► A three dimensional dose rates EAST device was obtained by this code.

Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , , ,