Article ID Journal Published Year Pages File Type
272440 Fusion Engineering and Design 2011 5 Pages PDF
Abstract

The optical diagnostic system of KSTAR consists of visible diagnostics including toroidal and poloidal Hα monitors, a visible survey spectrometer, and filterscopes. A re-entrant cassette made of stainless steel, containing five optical quartz windows has been developed to allow easy access of the visible diagnostics to the plasma. The configuration and manufacturing design of the diagnostic cassette and the installation of optical diagnostic systems within the cassette are described. The structural and thermal analysis of the diagnostic cassette and in situ calibration of optical diagnostics have also been performed. The optical lens system showed good image quality by spot diagram analysis.

Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , ,