Article ID Journal Published Year Pages File Type
272836 Fusion Engineering and Design 2009 8 Pages PDF
Abstract

A fast charge exchange recombination spectroscopy (CXRS) system has been developed for the real-time measurement and feedback control of ion temperature (Ti) profile and toroidal rotation velocity (Vt) in JT-60U. In order to control Ti and Vt in real-time, the charge exchange recombination spectroscopy with high time resolution, the real-time processor system, and the real-time control system have been developed. Utilizing this system, real-time control of the Ti gradient between r/a ∼ 0.25–0.5 has been demonstrated with neutral beams at high beta plasmas (normalized beta βN ∼ 1.6–2.8). The strength of the internal transport barrier is controlled. Moreover, the real-time control of Vt has been demonstrated from counter (anti-parallel to the plasma current, Ip) to co (parallel to the Ip) direction. Then the behavior of edge localized mode (ELM) is changed by controlling the Vt.

Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , , , , ,