Abstract

Different welding strategies were investigated to improve the tubular transition of CuCrZr to 316L in cooling pipes for actively cooled plasma facing components. Electron beam welding experiments have been carried out on tubular samples using different filler and adapter materials. After non-destructive testing by dye penetrant and He-leak tight testing samples were tensile tested at RT and 400 °C to down-select promising candidates. Furthermore samples were taken for a metallographic examination in order to determine the integrity of the welds, the depth of penetration and the hardness profile across the weld. In the scanning electron microscope the weld microstructure and the formation of phases were studied. Good results were obtained by the use of a Ni-filler, an Inconel and explosive welded adapter. The tested samples of these variations fulfilled the strength requirements according to the ITER specification and showed an improved transition compared with the current solution of a pure Ni-adapter. The final down-selection will be based on the results of fatigue and torsion testing.

Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , ,