Article ID Journal Published Year Pages File Type
2763315 Journal of Clinical Anesthesia 2011 5 Pages PDF
Abstract

Study ObjectiveTo investigate anesthetic techniques for robot-assisted endoscopic atrial septal defect (ASD) repair.DesignClinical observational study.SettingOperating room of a general military hospital.Patients56 adult, ASA physical status 1 and 2 patients undergoing elective general anesthesia.InterventionsAfter induction of general anesthesia, a left-sided, double-lumen endotracheal tube was positioned to allow single left-lung ventilation and contralateral CO2 pneumothorax (capnothorax). With ultrasound guidance, peripheral cardiopulmonary bypass (CPB) catheters were placed.Measurements and Main ResultsAll patients tolerated single left-lung ventilation before CPB; however, hypoxia (oxygen saturation < 90%) occurred in 11 (19.6%) patients post-CPB, which required treatment with continuous positive airway pressure. Fifteen (26.8%) patients had hypotension secondary to capnothorax, which was treated with transfusion and vasopressors. Aortic cross-clamp time was 43.6 ± 11.2 minutes, and CPB time was 106.7 ± 12.4 minutes. The median intensive care unit stay was 21 hours and postoperative hospital stay was 4 to 7 days.ConclusionsThe key issue for anesthetic management of robot-assisted totally endoscopic ASD repair is maintaining stable hemodynamics and oxygenation, especially during one-lung ventilation and capnothorax.

Related Topics
Health Sciences Medicine and Dentistry Anesthesiology and Pain Medicine
Authors
, , , , , , ,