Article ID Journal Published Year Pages File Type
281069 International Journal of Solids and Structures 2005 19 Pages PDF
Abstract

The paper describes a two-step finite element formulation for the thermo-mechanical non-linear analysis of the behaviour of the reinforced concrete columns in fire. In the first step, the distributions of the temperature over the cross-section during fire are determined. In the next step, the mechanical analysis is made in which these distributions are used as the temperature loads. The analysis employs our new strain-based planar geometrically exact and materially non-linear beam finite elements to model the column. The results are compared with the measurements of the full-scale test on columns in fire and with the results of the European building code EC 2. The resistance times of the present method and the test were close. It is also noted that the building code EC 2 might be non-conservative in the estimation of the resistance time.

Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering
Authors
, , , ,