Article ID Journal Published Year Pages File Type
2838262 Cardiovascular Revascularization Medicine 2006 7 Pages PDF
Abstract

AimThe incidence of restenosis within stented segment after intravascular brachytherapy with recommended dose prescription protocols is up to 25%. Therefore, we designed a randomized trial comparing recommended dose prescription protocol with dosing adjusted for the source-to-target distance.MethodsFifty-one in-stent restenosis (ISR) lesions in 48 patients underwent centered source β-irradiation with serial intravascular ultrasound. Patients randomly received 20 Gy at 1 mm either beyond lumen surface [n=25, standard group (S)] or external elastic membrane [n=26, dosing-adjusted (DA) group]. Minimum dose absorbed by 90% of adventitia (DV90%Adv) was calculated.ResultsDV90%Adv was higher for the DA group than for the S group (21.63±5.67 vs. 12.05±4.88 Gy, P<.001). After 8.9±4.5 months there was complete lumen preservation in DA vs. lumen decrease subsequent to neointimal hyperplasia (NIH) in S group (0.10±1.20 vs. −0.61±1.29 mm3/mm, P<.05). Vessel volume increased significantly in the DA group and was unchanged in S group (+1.73, P=.002 vs. 0.14 mm3/mm, P=NS). DV90%Adv correlated inversely with NIH volume and positively with vessel volume change (r=−.405, P=.007 and r=.363, P=.017, respectively).ConclusionFor β-irradiation of ISR, dosing adjusted for the source-to-target distance leads to significant increase in target delivered doses, which is associated with complete NIH inhibition and induction of positive vessel remodeling.

Related Topics
Life Sciences Biochemistry, Genetics and Molecular Biology Molecular Medicine
Authors
, , , , , , , , , , , ,