Article ID Journal Published Year Pages File Type
285364 Journal of Constructional Steel Research 2011 9 Pages PDF
Abstract

The bonding connection in steel–concrete composite beams is investigated in the case of static loading and normal strength concrete. Two 3-point bending tests performed on 4 meter span beams confirm that bonding could be very efficient allowing a large plastic strain without any shear failure if the bonding joint is properly designed. The measurements are close to the numerical results provided by non-linear beam models or non-linear FE model. However all the studied beam models do not allow a very accurate prediction of the behaviour close to the interface at failure in the case of shear failure. A realistic shear failure criterion suitable for bonded composite beams may improve numerical results.

Research highlights► Connection in steel–concrete beams–No shear failure if the bonding joint is properly designed. ► Modelling by FEM or non-linear beam approach (cross-sections divided into thin layers). ► Shear failure in the central zone of the beam–Realistic steel–concrete shear failure criterion required.

Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering