Article ID Journal Published Year Pages File Type
285714 Journal of Constructional Steel Research 2010 10 Pages PDF
Abstract

This paper describes a series of tests investigating methods to develop composite action in existing non-composite floor systems. Three types of 22-mm diameter post-installed shear connectors were tested under static and fatigue loading. Test results are compared with previous research results on 19-mm diameter, post-installed shear connectors as well as with conventional welded shear studs. Based on the test results, preliminary design equations are proposed for the static and fatigue strength of post-installed shear connectors. These post-installed shear connectors showed a significantly higher fatigue strength than conventional welded shear studs. The superior fatigue strength of these post-installed shear connectors enables the strengthening of existing bridge girders using significantly fewer shear connectors than possible with conventional welded shear studs.

Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering
Authors
, , ,