Abstract
A 78-year-old gentleman with a diagnosis of symptomatic severe xenograft aortic stenosis with multiple comorbidities was referred for transcatheter aortic valve implantation, that is, a “valve-in-valve” procedure. Transcatheter aortic valve implantation was performed by transapical approach using a balloon-expandable bioprosthesis. During valve deployment, the prosthesis moved toward the left ventricle and a second balloon-expandable valve was implanted within the first one-a “valve-in-valve-in-valve” to avoid further ventricular embolization of the first bioprosthesis. Echocardiography at hospital discharge showed a residual mean transvalvular gradient of 17 mm Hg and trivial paravalvular aortic regurgitation. At 1 year follow-up, the patient was in New York Heart Association functional class II.
Related Topics
Health Sciences
Medicine and Dentistry
Cardiology and Cardiovascular Medicine
Authors
Rodrigo MD, Ãric MD, Daniel MD, Robert MD, Josep MD,