Article ID Journal Published Year Pages File Type
2911382 EJVES Extra 2006 4 Pages PDF
Abstract

An 85-year-old man with left sided single kidney presented with end-stage renal failure after an acute intestinal bleeding. A complex bifurcational stenoses distally to a 6 months previously implanted ostial stent in the left renal artery was found on duplex imaging and angiogram. These two de-novo stenoses in the distal main renal artery and the proximal segment of the lower branch were simultaneously treated with a ultra-low profile, monorail bifurcation balloon catheter system (Avion Bifurcation RX2™, Invatec, Italy) that consists of a main vessel balloon (20/3.5 mm) and a side vessel balloon (20/2.75 mm). One day and three months postinterventionally, duplex ultrasound demonstrated no recurrent stenoses. Bifurcation balloon catheter systems for complex renal artery stenosis are discussed.

Related Topics
Health Sciences Medicine and Dentistry Cardiology and Cardiovascular Medicine
Authors
, , , ,