Article ID Journal Published Year Pages File Type
2914427 European Journal of Vascular and Endovascular Surgery 2008 5 Pages PDF
Abstract

ObjectivesThe aim of this study was to determine whether the collar graft (standard dacron graft with a customized flexible collar attached to the proximal rim) decreased anastomotic bleeding and the overall clamp time.DesignProspective randomised single center study.MethodsBetween November 2003 and January 2006, 21 patients were treated with a collar graft and 19 with a standard dacron graft. Routine endoaneurysmorraphy was used. Only infra-renal aneurysms between 5.5 cm and 6.5 cm were included. Aneurysms were diagnosed by CT scans. The total number of bleeding points, the total clamp time, and the number of teflon felt pledgets, was determined.ResultsThe total number of bleeding points; the number of aortic re-clamps and total clamp time (minutes) per patient were all significantly lower in the collar graft group (1.2 versus 2, p < 0.04; 0.5 versus 2.0, p < 0.001; 13.6 versus 20.1, p < 0.003 respectively). The number of teflon felt pledgets and new sutures used was significantly lower in the collar graft group (p < 0.001 and p < 0.003 respectively).ConclusionThe collar graft resulted in fewer anastomotic bleeding points and a shorter clamp time.

Related Topics
Health Sciences Medicine and Dentistry Cardiology and Cardiovascular Medicine
Authors
, , , , , ,