Article ID Journal Published Year Pages File Type
294872 Mining Science and Technology (China) 2009 5 Pages PDF
Abstract

The frictional performance of gaskets is greatly affected by frictional heat in operational mine hoists. Based on frictional mechanism and heat transfer theory, the mathematical model of the temperature field of the PVC gasket in an operational mine hoist was investigated, a numerical simulation using ANSYS is presented and the distribution of the temperature and heat flux were studied under basic assumptions. The results show that the temperature gradually decreases as the radius of the model increases and the isotherms are arcs of concentric semi-circle. The heat flux is of bilateral symmetry in the model and decreases radially. The theoretical values correspond with the measured values for a short time (τ ≤ 100 s) when the steel wire rope slides.