Article ID Journal Published Year Pages File Type
295269 NDT & E International 2012 6 Pages PDF
Abstract

An ultrasonic imaging system based on waveguide techniques was developed to provide in-service inspection of reactor core of a sodium-cooled fast reactor (SFR) and potential applications in other hostile environments. By using the ultrasonic waveguide techniques, we overcome the major technical challenge in developing an under-sodium viewing (USV) system that can withstand the high-temperature and corrosive environment. The chosen design of the prototype waveguide (WG) is a hybrid of bundle and spiraled-sheet WG. The prototypes show high detection sensitivity with minimal background noise by effectively reducing spurious echoes and mode conversions. Tests on prototype waveguide transducers were conducted in liquid sodium up to 340 °C (650 °F). C-scan images of the targets were successfully developed from both time-of-flight and amplitude variations of the reflected echoes. The ultrasonic waveguide imaging system demonstrates a capability of detecting defects with 1 mm width and 0.5 mm depth under molten sodium.

► Developed a novel ultrasonic waveguide technique for under-sodium imaging. ► Reduced the spurious echoes and mode conversions effectively. ► Demonstrated the imaging capability in molten sodium up to 650 °F successfully. ► Achieved defects detection with lateral resolution of 1 mm and vertical resolution of 0.5 mm.

Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering
Authors
, , , , , ,