2972936 The Journal of Heart and Lung Transplantation 2006 7 Pages PDF
Abstract
Monitoring of the C2 rather than the C0 level better reflects immunosuppressive efficiency and identifies patients at increased risk of acute rejection. A C2 level of >600 ng/ml should be the target to prevent acute rejection.