Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
297734 | Nuclear Engineering and Design | 2011 | 7 Pages |
Within the reactor safety research, the removal of decay heat from a debris bed (formed from corium and residual water) is of great importance. In order to investigate experimentally the long term coolability of debris beds, the scaled test facility “DEBRIS” (Fig. 1) has been built at IKE. A large number of experiments had been carried out to investigate the coolability limits for different bed configurations (Rashid et al., 2008, Groll et al., 2008 and Schmidt, 2004). Analyses based on one-dimensional configurations underestimate the coolability in realistic multidimensional configurations, where lateral water access and water inflow via bottom regions are favoured. Following the experiments with top- and bottom-flooding flow conditions this paper presents experimental results of boiling and dryout tests at different system pressures based on top- and bottom-flooding via a down comer configuration.A down comer with an internal diameter of 10 mm has been installed at the centre of the debris bed. The debris bed is built up in a cylindrical crucible with an inner diameter of 125 mm. The bed of height 640 mm is composed of polydispersed particles with particle diameters 2, 3 and 6 mm. Since the long term coolability of such particle bed is limited by the availability of coolant inside the bed and not by heat transfer limitations from the particles to the coolant, the bottom inflow of water improves the coolability of the debris bed and an increase of the dryout heat flux can be observed. With increasing system pressure, the coolability limits are enhanced (increased dryout heat flux).
Research highlights► Performing of dryout experiments with a polydispersed bed for top- and bottom-flooding. ► Study of influence of different down comer configurations on the coolability of debris bed. ► Measurement of temperature profiles, pressure drops and determination of dryout heat flux. ► Observation of noticeable increase in coolability of debris bed with the use of down comer is observed.