Article ID Journal Published Year Pages File Type
298048 Nuclear Engineering and Design 2010 12 Pages PDF
Abstract

In the frame of the OECD/NEA SETH project an experimental campaign has been carried out in the PANDA facility to investigate gas transport and mixing induced by a plume or a jet in the large-scale multi-compartment PANDA facility. The paper summarizes the results of the horizontal jet test series consisting of eight tests. Horizontal jets impinging on a vertical wall of one of the cylindrical PANDA containment vessels have been generated by changing various parameters, such as: type of injected fluid (steam or a mixture of steam and helium), fluid injection velocity, elevation (with respect to the containment vessel) of the injection exit, initial fluid composition in the vessels, and location of the vent line. The initial jet Froude number has been varied between 17 and 36 and in one of the test condensation occurred. The paper shows the effect of these parameters variation on the test evolution with respect to jet impingement location in the vertical curved wall and variation of impingement location as a function of buoyancy variation. Fluid mixing and stratification, characteristics of gas transport between the compartment and the effect of condensation on the overall phenomena evolution are analyzed in the paper.

Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , ,