Article ID Journal Published Year Pages File Type
298424 Nuclear Engineering and Design 2009 10 Pages PDF
Abstract

The thermal-hydraulic performance of the PCHE was investigated using the KAIST helium test loop. Experiments were performed in the helium laminar region with 350 < Re < 1200. The hot/cold side inlet conditions were 25–550 °C/25–100 °C over the operating pressure of 1.5–1.9 MPa, respectively. Mass flow rates were controlled in the range of 40–100 kg/h. Pressure drop and temperature difference were measured at the inlet and outlet of the hot and cold sides. A global Fanning factor correlation and a global Nusselt number correlation were proposed using information only at the inlet and outlet of the hot and cold sides. A three-dimensional (3-D) numerical simulation was performed using FLUENT, a commercial computational fluid dynamics (CFD) code, to compare simulation results to the KAIST helium test data and to obtain the local Nusselt number in the PCHE. CFD predictions showed good agreement with experimental data. A local pitch-averaged Nusselt number correlation was proposed using local temperature, pressure, surface heat fluxes, and properties provided by CFD simulations. The system analysis code, GAMMA, was also utilized to identify which correlation was more applicable for system analysis. It turns out that the proposed local pitch-averaged Nusselt number correlation from CFD simulations is more appropriate than the global Nusselt number correlation developed from experimental data.

Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology