Passive energy dissipating devices like elasto-plastic dampers (EPDs) can be used for retrofitting of structures subjected to seismic loads. A model of reinforced concrete structure is tested on shake table with and without EPDs attached in its frames. Using a finite element model of the structure, linear and nonlinear time history analysis is carried out using Newmark's time integration technique. However, the most viable approach used by designers is response spectrum approach. Hence equivalent linearization techniques are used to address the nonlinearity of dampers and iterative response spectrum method is used for evaluating the response of the structure using equivalent damping and stiffness. The analytical maximum storey response of the structure is compared with experimental values and time history analysis values. It has been concluded that, iterative response spectrum technique using equivalent linearization techniques is simple and results in reasonably acceptable response of the structures retrofitted with energy dissipaters.