Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
298768 | Nuclear Engineering and Design | 2008 | 10 Pages |
KAERI has performed a series of experiments to investigate the performance of a prototype sparger for the APR1400 in view of a dynamic load oscillation with a variation of the test conditions such as a discharged air mass, a submergence of the sparger, the valve opening time, and the pool temperature during an air clearing phase. The air mass and pool temperature are in the range of 0.8–1.5 kg and 20–90 °C, respectively. The valve opening time can be adjusted within the range of 0.6–1.8 s. The maximum positive pressure amplitude, which is observed at the bottom of the quenching tank, is increased with the maximum header pressure of the sparger. The valve opening time has a considerable effect on the maximum amplitude. As the opening time decreases, the maximum amplitude at the tank wall is increased. Air mass and pool temperature, however, have a weak effect on the maximum amplitude. Oscillation frequency is decreased with an increase of the air mass in the range of 2.5–4.5 Hz.