Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
299282 | Nuclear Engineering and Design | 2007 | 12 Pages |
Abstract
A detection of a defect of a helical heating tube installed in the fast breeder reactor “Monju” in Japan is done by a feeding of an eddy current testing (ECT) probe with magnetic sensor into the tube. An undesirable vibration of the ECT probe always happens under a certain condition and makes the inspection difficult. Several characteristics of the vibration have been made clear by some experiments using a mock-up, but the essential factor of the vibration is still unclear. In this paper, a numerical simulation of the vibration is implemented on the assumption that the vibration is caused by Coulomb friction. An analytical model, which is obtained as a lumped mass model, is a large-scale non-linear vibration system and many computational costs are ordinarily required to carry out the simulations. The Transfer Influence Coefficient Method is applied so that the simulation is efficiently carried out. The results of simulation qualitatively agree well with the experimental results. It confirms the validity of the assumption that the vibration is caused by Coulomb friction.
Related Topics
Physical Sciences and Engineering
Energy
Energy Engineering and Power Technology
Authors
Takumi Inoue, Atsuo Sueoka, Takeshi Maehara, Yutaka Nakano, Hiroyuki Kanemoto,