Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
299584 | Nuclear Engineering and Design | 2005 | 13 Pages |
In the direct vessel injection (DVI) system downcomer, the direct emergency core coolant (ECC) bypass is activated during the reflood phase of a large-break loss-of-coolant accident (LBLOCA) by the interaction between the downward-flowing liquid-film and the transverse gas flow. Direct ECC bypass is reportedly the major bypass mechanism of ECC, and various experiments have been performed to obtain detailed information about the ECC bypass in a DVI downcomer. These lead to a proposed new scaling methodology, named ‘modified linear scaling’, which is expected to preserve the phase distribution in the downcomer and the ECC bypass phenomena. In the present study, modified linear scaling was experimentally validated in air–water tests comprising Test 21-D of the upper plenum test facility (UPTF). The counterpart tests of UPTF Test 21-D were performed in 1/7.3 and 1/4.0 scale models of a UPTF downcomer, and the test results were compared with the experimental data of UPTF Test 21-D. Two important parameters of direct ECC bypass – the normalized liquid-spreading width on the downcomer wall and the direct ECC bypass fraction, which is the fraction of input water bypassed out the broken cold-leg – were considered in the validation. The comparison revealed that the scaling parameters of direct ECC bypass are well preserved in the prototype and reduced models, from which we conclude that the modified linear scaling methodology is appropriate for designing a reduced test facility and for a scaling analysis of direct ECC bypass in the reflood phase of an LBLOCA.