Article ID Journal Published Year Pages File Type
303064 Renewable Energy 2006 16 Pages PDF
Abstract

An economic evaluation of a hybrid wind/photovoltaic/fuel cell (FC) generation system for a typical home in the Pacific Northwest is performed. In this configuration the combination of a FC stack, an electrolyser, and hydrogen storage tanks is used as the energy storage system. This system is compared to a traditional hybrid energy system with battery storage. A computer program has been developed to size system components in order to match the load of the site in the most cost effective way. A cost of electricity, an overall system cost, and a break-even distance analysis are also calculated for each configuration. The study was performed using a graphical user interface programmed in MATLAB.

Related Topics
Physical Sciences and Engineering Energy Renewable Energy, Sustainability and the Environment
Authors
, , ,