Article ID Journal Published Year Pages File Type
3042278 Clinical Neurology and Neurosurgery 2008 4 Pages PDF
Abstract

ObjectiveF wave study is a simple, non-invasive method commonly utilized for evaluation of cervical root lesions. Its diagnostic sensitivity is low. There are no large series comparing F wave studies with MRI as a reference standard.Patients and methodsWe performed F wave studies in 30 controls (15 men; mean age: 50 years; standard deviation: 17.9 years; range: 21–80 years) and, prospectively, 31 patients (19 men; mean age: 48 years; standard deviation: 16.2 years; range: 26–79 years) referred for evaluation of cervical spondylotic radiculopathy (CSR). All patients’ MRIs were compared with F wave parameters.ResultsCombined utilization of minimal F latency, F chronodispersion, F persistence and side to side differences resulted in 55% sensitivity and 100% side concordance for detecting CSR, with MRI as a comparison standard. F wave parameters also provided complementary information to needle electromyography in the diagnostic evaluation of CSR. Although F waves were not indicative of radiculopathy levels, 4/31 (13%) of cases had at least one abnormal F wave parameter, despite normal electromyography findings.ConclusionsCombined utilization of multiple F wave parameters is a useful, diagnostic adjunct in the electrophysiological evaluation of CSR.

Related Topics
Life Sciences Neuroscience Neurology
Authors
, , , , , , ,