Article ID Journal Published Year Pages File Type
3048299 Clinical Neurophysiology 2005 9 Pages PDF
Abstract

ObjectiveTo determine whether, and under which conditions, transcranial electrical stimulation (TES) and transcranial magnetic stimulation (TMS) can activate similar neuronal structures of the human motor cortex, as indicated by electromyographic recordings.MethodsFocal TMS was performed on three subjects inducing a postero-anterior directed current (p-a), TES with postero-anteriorly (p-a) and latero-medially (l-m) oriented electrodes. We analyzed the onset latencies and amplitudes (single-pulse) and intracortical inhibition and excitation (paired-pulse).ResultsTMS p-a and TES p-a produced muscle responses with the same onset latency, while TES l-m led to 1.4–1.9 ms shorter latencies. Paired-pulse TMS p-a and TES p-a induced inhibition at short inter-stimulus intervals (ISI) (maximum: 2–3 ms) and facilitation at longer ISIs (maximum: 10 ms). No inhibition but a strong facilitation was obtained from paired-pulse TES l-m (ISIs 1–5 ms).ConclusionsOur findings support the hypothesis, that current direction is the most relevant factor in determining the mode of activation for both TMS and TES: TMS p-a and TES p-a are likely to activate the corticospinal neurons indirectly. In contrast, TES l-m may preferentially activate the corticospinal fibres directly, distant of the neuronal body.SignificanceTES is a suitable tool to induce intracortical inhibition and excitation.

Related Topics
Life Sciences Neuroscience Neurology
Authors
, , , , ,