There are several well defined indications for surgical management of humeral shaft fractures. Operative procedures on the humerus are associated with their own complications. Iatrogenic brachial artery injury as a complication of humeral shaft plating has not been reported previously. We report a case of a 48 years old female, who received operation at a district hospital and was referred to us when the surgeon could not palpate the pulse. CT angiogram showed that there was segmental non-opacification of the brachial artery. There was distal reformation and the thrombosis was decided to be managed conservatively. We believe that the arterial injury was a result of improper surgical technique and the segmental block might be due to improper use of plate holding forceps. This case report makes us aware of a rare complication of operative management of humeral shaft fractures and that basic principles of surgery must be always followed to prevent such injuries.