Article ID Journal Published Year Pages File Type
313192 Tunnelling and Underground Space Technology 2010 7 Pages PDF
Abstract

A new partial smoke extraction system for the Busan–Geoje immersed tunnel was investigated experimentally using simulated tunnel fires. The tests were performed in a 1:20-scale model tunnel with a smoke extraction duct between two traffic tubes. The fire corresponded to a 5-MW full-scale fire, based on Froude modeling. Isothermal and thermal experimental models were considered. The performance of the partial smoke extraction system was quantified under natural and longitudinal ventilation conditions. The results showed that the smoke extraction efficiency of the natural ventilation was 30% better than with longitudinal ventilation, because of smoke stratification in the tunnel. Additionally, the efficiency obtained from the thermal model was comparable to that from the isothermal model under both ventilation conditions. The results suggested that the use of a partial smoke extraction system without longitudinal ventilation improved the initial visibility during tunnel fires.

Related Topics
Physical Sciences and Engineering Earth and Planetary Sciences Geotechnical Engineering and Engineering Geology
Authors
, , , , ,