ObjectiveThe objective of this study was to examine the clinical and radiographic results of implants placed in fresh extraction sockets for 2 years of function.Study designTen patients were presented a treatment protocol involving the extraction of their remaining mandibular teeth and immediate placement of 4 implants (2 in fresh extraction sockets; test group (TG, n = 20), 2 in mature bone; control group (CG, n = 20). Descriptive statistics for the differences between baseline and follow-up values were assessed by chi-square test.ResultsNone of the implants lost osseointegration. The MPI Score 0 was 80.3% in SG, 82.7% in CG, and MPI Score 1 was 13.4% in SG and 14.9% in CG at the end of 1 year, and remained stable after 2 years. No significant difference in MPI, MBI, KMW, and PPD were observed between the baseline examination and controls. Chances in MBL in CG were slightly higher in SG.ConclusionPlacement of implants in fresh extraction sockets is a reliable treatment alternative.