Article ID Journal Published Year Pages File Type
3227467 The American Journal of Emergency Medicine 2006 4 Pages PDF
Abstract

ObjectivesThis study was designed to determine whether digital intubation is a valid option for definitive airway control by emergency physicians.MethodsDigital intubation was performed by 18 emergency medicine residents and 4 staff emergency medicine physicians on 6 different cadavers. Placement was confirmed by direct laryngoscopy. The total time for all attempts used, as well as the number of attempts, was recorded. Each participant attempted intubation on all 6 cadavers.ResultsFor 5 of the 6 cadavers, successful intubation occurred 90.9% of the time (confidence interval [CI], 85.5%-96.3%) for all participants. The average number of attempts for these 5 cadavers was 1.5 (CI, 1.4-1.7), and the average time required for success or failure was 20.8 seconds (CI, 16.9-24.8). The sixth cadaver developed soft tissue damage and a false passage near the vocal cords resulting in multiple failed attempts.ConclusionsAlthough the gold standard for routine endotracheal intubation remains to be direct laryngoscopy, its effectiveness in certain situations may be limited. We believe that digital intubation provides emergency physicians with another option in securing the unprotected airway.

Related Topics
Health Sciences Medicine and Dentistry Emergency Medicine
Authors
, , , , ,