Article ID Journal Published Year Pages File Type
3232197 Annals of Emergency Medicine 2010 7 Pages PDF
Abstract

Study objectiveWe determine whether the use of capnography is associated with a decreased incidence of hypoxic events than standard monitoring alone during emergency department (ED) sedation with propofol.MethodsAdults underwent ED propofol sedation with standard monitoring (pulse oximetry, cardiac and blood pressure) and capnography and were randomized into a group in which treating physicians had access to the capnography and a blinded group in which they did not. All patients received supplemental oxygen (3 L/minute) and opioids greater than 30 minutes before. Propofol was dosed at 1.0 mg/kg, followed by 0.5 mg/kg as needed. Capnographic and SpO2 data were recorded electronically every 5 seconds. Hypoxia was defined as SpO2 less than 93%; respiratory depression, as end tidal CO2 (etco2) greater than 50 mm Hg, etco2 change from baseline of 10%, or loss of the waveform.ResultsOne hundred thirty-two subjects were evaluated and included in the final analysis. We observed hypoxia in 17 of 68 (25%) subjects with capnography and 27 of 64 (42%) with blinded capnography (P=.035; difference 17%; 95% confidence interval 1.3% to 33%). Capnography identified all cases of hypoxia before onset (sensitivity 100%; specificity 64%), with the median time from capnographic evidence of respiratory depression to hypoxia 60 seconds (range 5 to 240 seconds).ConclusionIn adults receiving ED propofol sedation, the addition of capnography to standard monitoring reduced hypoxia and provided advance warning for all hypoxic events.

Related Topics
Health Sciences Medicine and Dentistry Emergency Medicine
Authors
, , , , ,