Abstract
Significant correlations were observed between TBSμCT and 3D microarchitecture parameters, regardless of the resolution. Correlations were detected that were strongly to intermediately positive for connectivity density (0.711 â¤Â r2 â¤Â 0.752) and trabecular number (0.584 â¤Â r2 â¤Â 0.648) and negative for trabecular space (â0.407 â¤Â r2 â¤Â â0.491), up to a pixel size of 1023 μm. In addition, TBSμCT values were strongly correlated between each other (0.77 â¤Â r2 â¤Â 0.96). Study results show that the correlations between TBSμCT at 93 μm and 3D microarchitecture parameters are weakly impacted by the degradation of image resolution and the presence of noise.