Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
3371395 | Journal of Hospital Infection | 2016 | 5 Pages |
SummaryThe non-tuberculous mycobacteria (NTM) Mycobacterium wolinskyi caused bacteraemia and massive colonization of an aortic prosthesis in a patient 16 days after cardiac surgery, necessitating repeat surgery and targeted antimicrobial chemotherapy. The infection control team investigated the source and conditions of infection. Peri-operative management of the patient complied with recommendations. The environmental investigation showed that although M. wolinskyi was not recovered, diverse NTM species were present in water from point-of-use taps and heater-cooler units for extracorporeal circulation. This case and increasing evidence of emerging NTM infections in cardiac surgery led to the implementation of infection control procedures in cardiac surgery wards.