A colorimetric cell proliferation assay for measuring neutralizing antibodies to influenza viruses in human sera is described. Following a 90-min incubation, the serum–virus mixture was transferred to Madin-Darby canine kidney cells cultured in 96-well plates. After further incubation for three days, a tetrazolium salt was added to the wells. Cellular mitochondrial dehydrogenases cleave the tetrazolium salt to formazan, and the resulting color change is read by a spectrophotometer. The absorbance values correlate directly to the number of viable cells in the assay well and thus also to the neutralizing activity of influenza-specific antibodies present in the serum. With the few hands-on manipulations required, this assay allows simultaneous testing of a considerable number of sera, offers opportunities for automation, and is suitable for use under biosafety level-3 conditions. The test was used to study the antibody response after the administration of seasonal, inactivated, trivalent influenza vaccine. Antibody titers determined by the neutralization test in pre- and post-vaccination serum pairs were compared with those obtained by the hemagglutination inhibition assay. The neutralization test yielded higher pre- and post-vaccination titers and a larger number of significant increases in post-vaccination antibody titer than the hemagglutination inhibition test. This new test format could serve as a valuable laboratory tool for influenza vaccine studies.